Specyfikacja produktuQSRN
Power supply24 V DC
Relay safety output3NO + 1NC (PNP or NPN)
Maximum switching capacity12 A (Distributed on all safety output contacts)
Transistor signal output<500 mA 24 V DC
Contact resistance<100 mΩ
Size117 × 100 × 22.5 mm
Class of pollution4 TYPE
CertificateISO, CE, UL, FCC, TUV
pobieranie
Zaktualizowano2024/11/23
Aby uzyskać więcej informacji
Safety Relay Product model
Model
QSRN
Certificate
ISO, CE, TYPE 4 
Output
Power supply
24 V DC
Tolerance of voltage
+10% / -20%
Power dissipation
2.9 W
Output
PNP  3NO + 1NC
Transistor signal output
<500 mA 24 V DC
Transistor signal output
<500 mA 24 V DC
Relay contact capacity
AC-1
6 A / 250 V AC / 1500 VA
AC-15
4 A / 240 V AC
DG-1
6 A / 24 V DC / 150 W
DG-13
4 A / 24 V DC
Maximum switching capacity
12 A (Distributed on all safety output contacts)
Contact resistance
<100 mΩ
Minimum load
10 mA / 5 V
Material of contact
AgSnO2 + 0.2µmAu
General parameter
Output fuse (external)
5 A gL/gG
Release response time
<30 ms (From input to output)
Check the resistance at the end of the input component(Touch edge/carpet)
1 kΩ ~ 10 kΩ
Electrical life
80,000 times
Cass of pollution
4 TYPE
Operating temperature
-25℃ ~ 85℃
Operating humidity
35% - 85% (No ice or condensation)
Impulse withstand voltage
2.5 kV
Level of protection
Enclosure IP30, terminal IP20, recommended for installation in cabinet or enclosure IP54
Storage temperature
-40℃ ~ 105℃
Shell material
Flame retardant PA66
Size
117 × 100 × 22.5mm

THE INSTALLATION OF THE CONTROLLER

1. Installation tools

 

(1) Electric drill, drill bit (specification: φ4.3, (φ5.2, φ6.8), tap (specification: M5,M6,M8).Cross and slotted screwdriver, hexagon wrench (specification: 6#.8#), adjustable wrench (specification: 22"), Needle nose pliers.etc

(2) The installation of the controller bracket requires a φ 5.2 drill and M6 tap

(3) The installation ofthe photoelectric support base requires a φ 6.8 drill bit and an M8 tap

(4) The fixing hole of the crimping buckle of the transmission line needs a φ 4.3 drill bit and an M5 tap

 

2. Installation of built-in controller

 Connect the controller directly to the 35mm electrical rail. lnstalled in the electrical cabinet of the machine.

THE INSTALLATION OF THE CONTROLLER
Safety light curtain connected to safety relay 2 circuit safety output wiring diagram
Safety light curtain connected to safety relay 2 circuit safety output wiring diagram
Optical synchronous 3&5 core safety light curtain connection QSRN safety relay wiring diagram
Optical Synchronous 3&5 Core Safety Light Curtain Connection QSRN Safety Relay Wiring Diagram
Controller Dimensional Drawing
Controller Dimensional Drawing
Safety relay -QSRN .STEP
QSRN technical data sheet
Ocena
  • Ładowanie ?????
Produkty powiązane
    Proszę o przesłanie informacji
    *Email
    imię i nazwisko
    *nagłówek
    *zawartość
    Prześlij
    • Obsługuje tylko .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maksymalnie 20M